Fleet enquiries for Africa[email protected]

Fire Truck CLW

Dongfeng 2,500L Fire Truck for Industrial Compounds, Warehouses & Estate Brigades

Engineered on the light-duty Dongfeng EQ1075DJ3CDF 4×2 chassis, this 2,500 L water-tank fire truck gives African warehouse parks, factories, agro-processing mills, and university campuses dedicated on-site fire standby. Its mechanical diesel powertrain, 6.04 m length, and onboard fire pump keep ownership and maintenance practical.

01 / Capability

Understand what the specification means.

Dedicated On-Site Water Reserve

2,500 L water tank (2,060 × 1,000 × 1,270 mm)

Bridges the critical first 3–5 minutes of a warehouse or yard fire before municipal engines arrive or site hydrants are pressurized.

Operating conditions
Calculated for initial handline or monitor flow of 8–14 L/s using the onboard water reserve alone.
What affects the result
Pump throttle speed, nozzle discharge setting, fire load intensity, and availability of factory ring-main hydrants.

Factory-Yard Maneuverability

3,308 mm wheelbase / 6,040 × 1,980 × 2,830 mm body

Threads safely between container stacks, loading aprons, and narrow factory fire lanes without requiring wide turning circles.

Operating conditions
Applies to the standard 4×2 CLW5070GXFSG25/DF chassis with 1,040 mm front and 1,692 mm rear overhang.
What affects the result
Yard paving quality, parked trailer clearances, gate widths, and overhead pipe-rack heights.

Workshop-Friendly Diesel Platform

Yuchai / Quanchai <150 hp diesel + Manual transmission

Allows standard commercial-vehicle mechanics at industrial sites to maintain routine filters, belts, and 7.00R16 tires locally.

Operating conditions
Assumes emission tier (Euro 2–6) is matched to regional diesel availability and workshop tooling.
What affects the result
Local spare-parts stocking, periodic pump seal exercising, and preventive battery/coolant checks during standby.

02 / Specification

The vehicle, system by system.

Industrial parks, commercial warehouses, textile mills, timber yards, and university campuses across Africa increasingly maintain their own first-response fire truck rather than waiting solely for distant municipal stations. The CLW 2500L Dongfeng Fire Truck (CLW5070GXFSG25/DF) delivers dedicated on-site suppression in an economical 7,135 kg GVW package built on the familiar Dongfeng EQ1075DJ3CDF 4×2 commercial chassis.

Site-Ready Simplicity & Low Operating Overhead

Because facility emergency teams often rely on general commercial-truck mechanics rather than specialized fire-apparatus workshops, this model uses a straightforward manual transmission and a Yuchai or Quanchai diesel engine under 150 hp, running on widely available 7.00R16 / 7.00R16LT 14PR tires. Its 2,500 L water tank (2,060 × 1,000 × 1,270 mm) and 6,040 × 1,980 × 2,830 mm dimensions maneuver cleanly between loading docks, storage sheds, and factory perimeter roads.

  • Rapid On-Compound Deployment: Reaches speeds up to 100 km/h on estate roads and engages its onboard fire pump and roof fire monitor within seconds of arrival at a warehouse bay or generator enclosure.
  • Hydrant & Storage-Pond Compatibility: Operates independently on its 2,500 L reserve or connects to factory fire-main hydrants for sustained cooling of neighboring structures.
  • Multi-Site Fleet Scalability: Competitive entry pricing supports equipping multiple factories or plantation estates under one contract, with tiered unit pricing and phased batch delivery.

Facility safety managers confirm steering side (LHD/RHD), local diesel emission tier (Euro 2–6), coupling type, and optional warning strobes prior to factory build.

Chassis & powertrain
Vehicle Model No.
CLW5070GXFSG25/DF
Chassis Model
Dongfeng EQ1075DJ3CDF (4×2)
Engine Brand & Output
Yuchai / Quanchai Diesel, <150 hp
Emission Standard
Euro 2 / 3 / 4 / 5 / 6 configurable
Transmission
Manual
Wheelbase
3,308 mm
Front / Rear Overhang
1,040 / 1,692 mm
Tire Specification
7.00R16, 7.00R16LT 14PR
Body & tank
Body Type
Water Tank Fire Truck (Tanker)
Overall Dimensions (L×W×H)
6,040 × 1,980 × 2,830 mm
Water Tank Capacity
2,500 L (2.5 m³)
Tank Dimensions
2,060 × 1,000 × 1,270 mm
Equipment Compartments
Lockable side tool lockers for facility hoses and wrenches
Working equipment
Main Firefighting Equipment
Fire Pump and Roof-Mounted Fire Monitor
Extinguishing Agent
Water
Pump Engagement
PTO driven from manual gearbox
Water Supply Interface
Top tank fill hatch, hydrant refill inlet, and hose discharge outlets
Operating performance
Gross Vehicle Weight (GVW)
7,135 kg
Curb Weight
4,260 kg
Rated Payload
2,500 kg
Maximum Road Speed
100 km/h
Safety equipment
Warning Lighting
Roof emergency warning beacon and optional red strobe lights
Commercial Tire Load Margin
7.00R16LT 14PR tires specified for continuous full-tank standby readiness
Low-Weight Structural Footprint
7,135 kg GVW protects factory drains, weighbridge aprons, and paved walkways
Configuration options
Red Strobe Lights
Optional high-visibility warning strobes for industrial yards
Steering Configuration
Left-hand drive (LHD) or right-hand drive (RHD)
Factory Hydrant Adapter Kit
Optional BS336, Storz, or flanged site-hydrant fill couplings
Portable Extinguisher & PPE Racks
Optional locker brackets for CO2/dry-powder bottles and helmets

03 / Applications

Choose for the work ahead.

Suitable duties

  • Private manufacturing plants, warehouse parks, and agro-processing facilities
  • University campuses, hospital complexes, and large commercial estates
  • Industrial compounds with existing ring-main hydrants needing a mobile pumper
  • Multi-site corporate groups standardizing entry-level fire readiness across branches
  • Paved and graded compacted-gravel estate perimeter roads

Outside the intended duty

  • Chemical plants or fuel storage terminals requiring onboard foam blanketing
  • Off-road savannah bushfire or remote quarry work needing 4×4 drive
  • High-volume municipal firefighting where 7,000–15,000 L onboard storage is mandated
  • Elevated industrial rack or roof firefighting requiring aerial boom reach

04 / Procurement

A clearer brief. A better fleet fit.

  • Destination country, port, and LHD/RHD steering requirement
  • Existing site hydrant coupling type and fire-main pressure
  • Preferred emission standard (Euro 2 through Euro 6) for local fuel
  • Required hose lengths, branch nozzles, and locker tool layout
  • Number of facility units and delivery timeline across branches
Is a 2,500 L fire truck suitable as the primary standby truck for an industrial warehouse park?

For warehouse parks and manufacturing compounds equipped with yard hydrants or fire-water storage tanks, a 2,500 L truck provides immediate first-strike attack while crews connect supply hoses to the site main. For remote sites without hydrants, a larger 7,000 L or 8,000 L model is recommended.

Can our plant mechanics service the Dongfeng EQ1075DJ3CDF chassis locally?

Yes. The chassis uses a conventional manual gearbox, widely stocked 7.00R16 commercial tires, and a Yuchai or Quanchai diesel engine that can be ordered in Euro 2 through Euro 6 specification to match local workshop diagnostic tools.

Can we buy one unit for our main factory now and additional units for regional branches later?

Yes. Minimum order quantity is 1 unit, and if you commit to a multi-unit corporate fleet order, tiered pricing reduces the unit price with optional phased batch delivery across your project rollout.

Buying guide

Plan the right specification.

Your fleet. Your requirements.

Let’s configure your next vehicle.

Share the duty, destination and quantity. Include the details below so CLW can prepare a configuration and quotation for your project.

[email protected] ↗