Fleet enquiries for Africa[email protected]

Fire Truck CLW

Dongfeng 4,000L Fire Truck for Municipal & Secondary-City Response

Built on the 4×2 Dongfeng EQ1125SJ8CDC diesel chassis, this 4,000 L water-tank fire truck serves African municipal brigades and suburban stations tackling residential, roadside, and market structural fires. Its 6.86 m body navigates town streets smoothly while delivering independent fire pump and monitor knockdown where street hydrants are sparse or low-pressure.

01 / Capability

Understand what the specification means.

Onboard Water Reserve

4,000 L (approx. 3.3–6.7 minutes continuous discharge at 10–20 L/s)

Sustains initial Class A structural knockdown while crews establish hydrant supply or relay tankers.

Operating conditions
Calculated from the 4,000 L nominal water tank assuming standard single-line handline or moderate monitor flow of 10–20 L/s.
What affects the result
Selected fire pump flow rate, nozzle orifice setting, operating pressure, and simultaneous hose line usage.

Urban Maneuvering Envelope

6,860 × 2,210 × 2,880 mm overall dimensions

Accesses suburban lanes, town market streets, and low-clearance gateways that block 8–12 m heavy fire tenders.

Operating conditions
Applies to the standard CLW5100GXFSG40/DF 4×2 build with 1,130 mm front and 1,930 mm rear overhang.
What affects the result
Chosen wheelbase variant (3,600–4,700 mm), parked-street congestion, turning-circle curbs, and overhead utility cables.

Rapid Corridor Transit

Up to 95 km/h max speed (150–250 hp diesel)

Cuts response travel time across peri-urban ring roads and inter-town highways under full 10,400 kg GVW load.

Operating conditions
Based on paved level road operation using Yuchai/Yunnei manual powertrain in serviceable mechanical condition.
What affects the result
Road surface grade, traffic density, selected rear-axle ratio, and local speed policies for loaded emergency vehicles.

Balanced Axle & Payload Architecture

10,400 kg GVW / 5,950 kg curb weight / 4,000 kg rated load

Supports full water load plus crew and firefighting tools without overloading light-to-medium municipal pavements and culverts.

Operating conditions
Assumes standard split-section tank layout (front 1,195×1,000×1,250 mm, rear 1,000×2,160×1,250 mm) filled with water.
What affects the result
Added rescue tools, optional roof equipment, tire ply rating (14PR/16PR), and destination country axle-weight limits.

02 / Specification

The vehicle, system by system.

The CLW 4000L Dongfeng Fire Truck (model CLW5100GXFSG40/DF) is engineered for municipal stations, district fire posts, and suburban commercial zones across Africa where hydrant spacing is uneven and street widths restrict longer heavy tenders. Mounted on the proven Dongfeng EQ1125SJ8CDC 4×2 diesel chassis with a 10,400 kg gross vehicle weight, the vehicle carries a dedicated 4,000 L water tank within an agile 6,860 × 2,210 × 2,880 mm envelope.

Chassis Integration & Field Deployment

Powered by a Yuchai or Yunnei diesel engine in the 150–250 hp class paired with a manual transmission, this unit achieves up to 95 km/h on paved approach corridors while maintaining manageable axle loading on township roads. Its split-section tank geometry (front 1,195 × 1,000 × 1,250 mm and rear 1,000 × 2,160 × 1,250 mm) keeps the center of gravity balanced during rapid cornering and braking.

  • Immediate On-Scene Knockdown: Onboard fire pump and roof-mounted fire monitor allow crews to attack residential, market, and roadside fires immediately upon arrival before relay hoses are established.
  • Configurable Wheelbase & Tires: Multiple chassis wheelbase options (3,600–4,700 mm) and commercial tire ratings up to 16PR adapt the build to local road surfaces and spare-parts inventories.
  • Flexible Fleet Procurement: Available from a single station vehicle to multi-district municipal programs with tiered volume pricing and phased batch delivery aligned to local commissioning schedules.

Before final quotation, fleet engineers specify steering side (LHD or RHD), required Euro 2 to Euro 6 emission tier, hose locker layout, and destination port so every unit arrives ready for brigade integration.

Chassis & powertrain
Vehicle Model No.
CLW5100GXFSG40/DF
Chassis Model
Dongfeng EQ1125SJ8CDC (4×2)
Engine Brand & Output
Yuchai / Yunnei Diesel, 150–250 hp
Emission Standard
Euro 2 / 3 / 4 / 5 / 6 configurable
Transmission
Manual
Wheelbase Options
3,600 / 3,800 / 3,950 / 4,050 / 4,100 / 4,400 / 4,700 mm
Front / Rear Overhang
1,130 / 1,930 mm
Tire Specifications
245/70R19.5 (16PR), 8.25R20 (14PR/16PR), or 255/70R22.5 16PR
Body & tank
Body Type
Water Tank Fire Truck (Tanker)
Overall Dimensions (L×W×H)
6,860 × 2,210 × 2,880 mm
Water Tank Capacity
4,000 L (4.0 m³)
Split Tank Dimensions
Front 1,195 × 1,000 × 1,250 mm; Rear 1,000 × 2,160 × 1,250 mm
Equipment Storage
Integrated side equipment compartments with top-deck monitor access
Working equipment
Primary Firefighting Hardware
Onboard Fire Pump and Roof-Mounted Fire Monitor
Extinguishing Agent
Water
Pump Drive Arrangement
Chassis-driven PTO with manual transmission engagement
Water Delivery Modes
Roof monitor jet/spray discharge and side hose-outlet feeds
Operating performance
Gross Vehicle Weight (GVW)
10,400 kg
Curb Weight
5,950 kg
Rated Payload
4,000 kg
Maximum Road Speed
95 km/h
Safety equipment
Emergency Warning Lighting
Configurable emergency roof lightbar and optional red strobe lights
Weight Distribution Geometry
Split front-and-rear tank layout for controlled road stability under load
Heavy-Duty Tire Ratings
14PR to 16PR commercial radial tires rated for loaded fire-response duty
Configuration options
Red Strobe Lights
Optional high-visibility perimeter and roof warning strobes
Steering Configuration
Left-hand drive (LHD) or right-hand drive (RHD) per destination country
Fire Hose & Coupling Kit
BS336, Storz, or local municipal coupling adapters and delivery hoses
Scene Floodlighting & Siren
Optional PA siren unit and night-scene work lamps

03 / Applications

Choose for the work ahead.

Suitable duties

  • Municipal and district fire stations serving secondary cities and growing suburbs
  • Paved urban grids and compact laterite town streets where 2.21 m width aids passage
  • Residential, retail market, and roadside Class A solid-combustible fire incidents
  • Fleets prioritizing accessible Yuchai/Yunnei diesel parts and manual-gearbox serviceability
  • Multi-station government tenders requiring uniform medium-duty water pumpers

Outside the intended duty

  • Large hydrocarbon tank-farm or fuel-depot fires requiring dedicated foam tanks
  • Deep mud, soft sand, or ungraded off-road forestry tracks requiring 4×4 drive
  • High-rise aerial rescue or elevated-stream operations needing turntable ladders
  • Extended remote fires far from water sources without relay tanker support

04 / Procurement

A clearer brief. A better fleet fit.

  • Destination African country, port of discharge, and LHD/RHD requirement
  • Required local diesel emission tier (Euro 2 through Euro 6)
  • Preferred hose coupling standard (BS336, Storz, Gost, or NST)
  • Desired pump operating flow/pressure point and monitor type
  • Total fleet quantity and whether phased batch shipment is needed
  • Crew seating configuration and any bundled rescue-tool lockers
Why choose this 4,000 L Dongfeng 4×2 model instead of a smaller 2,500 L fire truck?

At 6,860 × 2,210 mm, this model remains compact enough for municipal neighborhood streets while carrying 60% more onboard water (4,000 L vs. 2,500 L). That extra volume gives crews significantly longer initial attack time in African districts where street hydrants are spaced far apart or have low line pressure.

Can the Dongfeng EQ1125SJ8CDC chassis be matched to local fuel quality in Africa?

Yes. The Yuchai or Yunnei diesel powertrain can be specified from Euro 2 through Euro 6 in the 150–250 hp band, allowing buyers to align engine injection and exhaust architecture with regional diesel sulfur levels and workshop diagnostics.

Does this 4,000 L unit handle flammable liquid fires at fuel stations?

This base CLW5100GXFSG40/DF configuration is a pure 4,000 L water tanker intended for Class A structural and general firefighting. If your response zone includes fuel stations or oil storage, consider a dual water-and-foam configuration such as the 4,800 L foam model.

How are multi-unit municipal orders priced and shipped?

Pricing is tiered by order volume—larger unit counts lower the FOB unit price. For regional fire-service rollouts, Chengli supports phased batch production and shipment via RO-RO or bulk vessel to major African ports based on your commissioning schedule.

Buying guide

Plan the right specification.

Your fleet. Your requirements.

Let’s configure your next vehicle.

Share the duty, destination and quantity. Include the details below so CLW can prepare a configuration and quotation for your project.

[email protected] ↗